Composite ducts

A panel specification is only part of a duct system.

Your overseas drawings may use a familiar duct description. A proposed composite system in China needs review of its panel construction, assembly details and intended service.

We install the accepted duct system to the approved drawings and applicable product technical documents.

What the panel system means

A composite duct uses a panel assembly whose core, facings and joining method are defined by the selected product. The term does not identify a universal material or establish a universal fire performance.

Confirm the product identity, intended service and applicable technical documents. Dimensions, material selection and assembly details follow the project design and product documentation.

China and overseas specifications need a common basis

Compared with a duct specification written for another jurisdiction, a China project requires confirmation that the proposed system satisfies the Chinese project design basis. Similar terminology does not prove that panels, performance evidence or installation methods are equivalent.

Compliance with IBC or applicable NFPA standards does not establish Chinese acceptance. For fire-related applications, confirm how GB 50016-2014 and the applicable mandatory requirements are addressed in the project’s fire design basis.

Read the code comparison before approving a substitution.

Cross-section of a composite duct panel Cut-away cross-section through one wall of a composite duct, showing an outer facing, a core and an inner facing, with a note that core and facings are defined by the selected product. Conceptual only, not a product specification or an installation detail. Outer facing Core Inner facing Facings and core are defined by the selected product — they are not fixed by the term "composite duct". Panel thickness, facings, core and the joining method are reviewed together. Conceptual only — not a product specification, not a substitute for the product technical documents.
The word does not define the build-up. A composite duct is a panel assembly: facings, a core and a joining method. Which facing, which core and which joint belongs to the selected product, so the panel data has to be read against the assembly it is proposed for.

How to review a proposed duct system

  1. Confirm whether the duct serves ventilation, air conditioning or another specified function.
  2. Review the proposed panel assembly and technical evidence against that function.
  3. Coordinate joints, supports, access provisions and penetrations with adjacent construction.
  4. Record the designer’s acceptance and agree inspection and handover requirements.

Keep the interfaces visible

The project may require separate review of seismic restraint and fire wrapping. A duct material choice does not resolve either requirement by itself.

Any proposed use for smoke exhaust requires project-specific review of the complete assembly and its supporting evidence.

Common questions

Can composite ducts replace the ducts specified in overseas drawings?

Only after the project designer reviews and accepts the proposed substitution. Compare the intended service, panel construction, joints, supports and documented performance with the project requirements. A similar product name does not establish equivalence. Update the approved drawings and installation details where the accepted substitution changes the system or its interfaces.

Is a composite panel test report enough to approve a duct system?

No. A panel report supports only the properties and scope it actually covers. The project also needs to assess the duct assembly, including joints, supports, openings and intended service. Ask the designer to confirm which evidence is required and whether the submitted documents cover the proposed installed configuration before accepting the system.

Can a composite duct be used for smoke exhaust?

Do not assume suitability from the word composite. Use for smoke exhaust requires confirmation against the project’s fire and smoke-control design and the product’s documented application. The project designer must review the proposed complete assembly. If the available technical evidence does not cover that use, the proposal needs further review before installation.

Review the proposed system before changing the drawings.

Send the duct function, relevant specification and proposed product documents.

Discuss composite ducts